IECC Climate Zones: County Lookup and HVAC Limits
By Danish Javaid, founder & editor · Published · Updated

To find your IECC climate zone, look up your county, not your ZIP code, in the climate-zone table your building department has adopted (in the 2021 IECC it is Table R301.1, with the map in Figure R301.1). The result is a number from 1 to 8 and usually a letter, such as 5A for Cook County, Illinois. That zone tells you which energy-code insulation and window row applies to your house; it does not give you a design temperature or an equipment size.
Find your zone in four steps
- Identify the county or equivalent jurisdiction where the house stands.
- Ask the building department which energy-code edition applies and whether the state amended the map. Some states do; Minnesota, for example, has proposed replacing the base county table with its own list.
- Read the county row in that edition's table and write down the edition and the result.
- If a generic web map disagrees with the adopted table, the adopted table wins; settle the difference before applying insulation or window requirements.
Assignments change between editions. The 2021 IECC adopted a revised zone map aligned with ASHRAE's zones, and the 2024 IECC kept the 2021 zones, so a house permitted under an older edition may sit in a different zone than a map published today shows.
Example lookups
| City | County | Zone (2021 IECC) |
|---|---|---|
| Miami, FL | Miami-Dade County | 1A |
| Houston, TX | Harris County | 2A |
| Phoenix, AZ | Maricopa County | 2B |
| Atlanta, GA | Fulton County | 3A |
| Dallas, TX | Dallas County | 3A |
| Las Vegas, NV | Clark County | 3B |
| San Francisco, CA | San Francisco County | 3C |
| Baltimore, MD | Baltimore City | 4A |
| Seattle, WA | King County | 4C |
| Chicago, IL | Cook County | 5A |
| Denver, CO | Denver County | 5B |
| Minneapolis, MN | Hennepin County | 6A |
| Duluth, MN | St. Louis County | 7 |
| Fairbanks, AK | Fairbanks North Star Borough | 8 |
Decode the label
| Part | Meaning | What it hints at |
|---|---|---|
| 1 to 8 | Thermal zone: lower is hotter, higher is colder | Cooling and solar control versus heating and heat loss |
| A | Moist | Humid summers; latent capacity matters |
| B | Dry | Smaller outdoor-air moisture load, never zero |
| C | Marine | Ocean-moderated, narrow seasonal swings |
| 7 and 8 | No moisture letter | Very cold and subarctic |
Phoenix (2B), Houston (2A), and Miami (1A) are all hot, but a house in Houston and one in Phoenix with the same sensible load still need different moisture removal. Atlanta (3A), Las Vegas (3B), and San Francisco (3C) share Zone 3 and have almost nothing else in common.
What the zone does control: the code envelope
Prescriptive code tables ask for more insulation, lower window U-factors, and tighter construction as zone numbers climb, and hot zones lean on a low solar heat gain coefficient instead. The steps are not even, so read your zone's row rather than interpolating. Air leakage shows it: the 2021 IECC (section R402.4.1.2) sets a blower-door limit of 5 air changes per hour at 50 pascals in zones 1 and 2 and 3 in zones 3 through 8, and local amendments change the number in some places, so confirm what your jurisdiction adopted. A cold-zone house built to current requirements generally needs much less heating capacity than the same house built to older ones, which is why a load calculation asks for the envelope and the climate.
What the zone does not control: the load
A zone spans many elevations and design weather values. For sizing, use station design temperatures and the measured envelope; the design temperature guide shows where they come from. To see the temperature effect by itself, use this site's one screening profile per zone (design temperatures of 50°F in Zone 1, 5°F in Zone 5, and −15°F in Zone 7; these are screening values, not station data) on one house with an overall heat-loss coefficient of 450 BTU/h per °F, and on the same house after air sealing and insulation bring it to 350.
| Zone profile (example city) | ΔT from 70°F | Load at 450 | Load at 350 | Saved by upgrade |
|---|---|---|---|---|
| 1 (Miami), 50°F | 20°F | 9,000 BTU/h | 7,000 BTU/h | 2,000 BTU/h |
| 5 (Chicago), 5°F | 65°F | 29,250 BTU/h | 22,750 BTU/h | 6,500 BTU/h |
| 7 (Duluth), −15°F | 85°F | 38,250 BTU/h | 29,750 BTU/h | 8,500 BTU/h |
From Zone 1 to Zone 7 the same house's heating load rises by a factor of 4.25 (38,250 ÷ 9,000), and the same 100 BTU/h-per-°F upgrade saves four times as much, 8,500 versus 2,000 BTU/h. That is why energy codes ask for more envelope as the zone number rises. It also means the zone alone cannot turn into a load: a screening profile per zone, like the one in the home load calculator, gives an early estimate, and the same-house-in-eight-climates comparison shows the full spread.
Sources: the climate-zone table and map are in Chapter 3 of the International Energy Conservation Code, 2021 edition (Table and Figure R301.1), published by the International Code Council; read the text your jurisdiction adopted. Related: BTU estimate, U-value estimate, and the methodology page on how this site's calculators use zone profiles.
Calculation guidance is reviewed against our published methodology. To report an error or request a correction, use the contact page.
Written and maintained by Danish Javaid, founder & editor. About this site.
Revision history
- : Rewrote as a lookup guide with a four-step county procedure and a decoder table; replaced the invented design temperatures with a Zone 1, 5, and 7 comparison using this site's zone profiles, and removed a dead DOE analysis link.